Troubleshooting – Tecfluid TM Series User Manual
Page 19

19
10
TROUBLESHOOTING
Problem
Probable cause
Solution
The associated 
electronics does not 
totalize 
Blockage or friction of the 
turbine propeller by particles 
Install a filter according to 
specification (maximum mesh 
size = 200 µm). 
Damaged pickup
Change the pickup
Disconnected cables between 
the turbine and the associated 
electronics 
Check the cable connection
The associated 
electronics totalize less 
than the actual volume 
Blockage or friction of the 
turbine propeller by particles 
Install a filter according to 
specification (maximum mesh = 
200 µm). 
The associated 
electronics totalizes 
more than the actual 
volume 
 
Presence of air pockets
Control the minimum tank level. 
Provide an air degasser 
upstream of the turbine if air 
intakes can be expected. 
Excessive emptying of storage 
tanks 
The pipe is not completely full
Make sure that the pipe is 
completely full, for example, 
installing the flowmeter in a 
vertical pipe with upwards flow 
Straight pipe sections before 
and after the flowmeter have not 
been kept 
Check that there are enough
straight pipe sections as 
indicated in point 3.4. 
The flow rate indicated by 
the associated equipment 
is unstable 