beautypg.com

Control from the rc-601mkii, Control from the rs-232c interface, External control – Teac CD-601MKII User Manual

Page 26: Setting operation on the cd player, Setting the baud rate

background image

26

TASCAM CD-601MKII

EXTERNAL CONTROL

Control from the RC-601MKII

Functions are added to the CD player and the CD player
becomes easier to user by using the Remote Control Unit
RC-601MKII (sold separately).

Expanded and additional functions by the
RC-601MKII

• Time chart/index search using the numeric keys

• Search using the jog/search dial

• End check function that allows you to listen to the end of

tracks

• 1 tune repeat, all tunes repeat, program repeat, repeat

playback between A and B

• Max. 10 cue points can be set to a single disc.

• Flash start function using 10 cue points

• Cue point settings for 500 discs can be stored to

memory.

• Playback between A and B using MEMO points and

confirmation playback of points are possible.

• The monitor outputs of up to four CD-601MKII can

be connected to RC-601MKII and monitored on
headphones.

Setting operation on the CD player

Operation on the CD player can be selected between
enabled and disabled when the RC-601MKII is connected.

Set enable/disable using menu No. 17 (“RMT”).

R_L (REMOTE + LOCAL, default): Operation of the CD

player is possible on both the RC-601MKII and the CD
player.

R (REMOTE): Operation of the CD player is possible on

only the RC-601MKII.

Operation of the CD player except the OPEN/CLOSE

key is disabled.

When the RC-601MKII is not connected, operation of the
CD player is enabled regardless of the setting of this item.

Control from the RS-232C interface

The CD player can be controlled on the serial interface
from a PC or other external equipment using the REMOTE
(SERIAL)
terminal (15-pin D-Sub connector, RS-232C-
compliant) on the rear panel. For details, contact us.

Pin Arrangement

Pin No. Signal Name IN/OUT

1

SHIELD

Shielded (shell ground)

2

RX

IN

Receive data

3

(Reserved)

Reserved

4

(Reserved)

Reserved

5

(Reserved)

Reserved

6

GND

Ground

7

(Reserved)

Reserved

8

(Reserved)

Reserved

9

TX

OUT

Send data

10

(Reserved)

Reserved

11

(Reserved)

Reserved

12

(Reserved)

Reserved

13

(Reserved)

Reserved

14

(Reserved)

Reserved

15

(Reserved)

Reserved

Setting the baud rate

When the REMOTE (SERIAL) terminal is used to control
the CD player, select the appropriate baud rate from the
following using menu No. 23 (“RS232C”).

B-0: (default when RC-601MKII is connected)

B-1: 1,200

bps

B-2: 2,400

bps

B-3: 4,800

bps

B-4: 9,600

bps

B-5: 19,200

bps

B-6: 38,400

bps

1
9

8

15