beautypg.com

Cleaning and maintenance, Inspecting burners – Desa VFRMV18PB User Manual

Page 20

background image

www.desatech.com

116412-01B

20

INSPECTING BURNERS

Continued

BURNER FLAME PATTERN

Figure 25 shows correct burner flame pattern.

NOTICE: Do not mistake orange

flames with yellow tipping. Dirt

or other fine particles are burned

by heater, causing brief patches

of orange flame.

If burner flame pattern is incorrect, as shown in

Figure 26

• turn heater off (see To Turn Off Gas to Appli-

ance, page 17)

• see Troubleshooting, page 22

The flames from the burner travel horizontally

through the log set and emerge at the middle and

rear of the set against the back logs.

The flames are blue off the burner and as they

progress through the log set, change to a light

yellow color, yellow decorative flames are visible

as the flames exit the log set.

The base of the log set and the underside of the

top logs glow red. Natural gas models will burn

with more blue flame, while propane gas model

will burn with bright yellow flame.

Figure 25 - Correct Burner Flame Pattern

Figure 26 - Incorrect Burner Flame

Pattern

Blue and Bright
Yellow Flames

Darker Orange
Flames

CLEANING AND

MAINTENANCE

WARNING: Turn off heater

and let cool before cleaning.

CAUTION: You must keep

control areas, burners and

circulating air passageways

of heater clean. Inspect these

areas of heater before each use.

Have heater inspected yearly

by a qualified service person.

Heater may need more frequent

cleaning due to excessive lint

from carpeting, pet hair, bedding

material, etc.

WARNING: Failure to keep

the primary air openings of the

burner clean may result in soot-

ing and property damage.

BURNER INjECTOR HOLDER AND
PILOT AIR INLET HOLE

The primary air inlet openings allow the proper

amount of air to mix with the gas. This provides

a clean burning flame. Keep these holes clear of

dust, dirt, lint and pet hair. Clean these air inlet

openings prior to each heating season. Blocked

air openings will create soot. We recommend

that you clean the unit every three months during

operation and have heater inspected yearly by a

qualified service person.

We also recommend that you keep the burner

tube and pilot assembly clean and free of dust and

dirt. To clean these parts we recommend using

compressed air no greater than 30 PSI. Your local

computer store, hardware store or home center

may carry compressed air in a can. You can use a

vacuum cleaner in the blow position. If using com-

pressed air in a can, please follow the directions on

the can. If you don't follow directions on the can,

you could damage the pilot assembly.

This manual is related to the following products: