MANTEL CLEARANCES

In addition to meeting noncombustible material

clearances, you must also meet required clearances

between fireplace opening and mantel shelf. If

you do not meet the clearances listed below, you

will need a hood.
Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel

shelf and top of fireplace opening, a hood is not

required (see Figure 6).
Determining Minimum Mantel Clearance
When Using a Hood

If minimum clearances in Figure 6 are not met, you

must have a hood. When using a hood there are

still certain minimum mantel clearances required.

Follow minimum clearances shown in Figure 7

when using hood.

INSTALLATION

Continued

Figure 6 - Minimum Mantel Clearances

Without Using Hood

Figure 7 - Minimum Mantel Clearances

When Using Hood

NOTICE: Surface temperatures

of adjacent walls and mantels be-

come hot during operation. Walls

and mantels above the firebox

may become hot to the touch.

If installed properly, these tem-

peratures meet the requirement

of the national product standard.

Follow all minimum clearances

shown in this manual.

NOTICE: If your installation does

not meet the minimum clear-

ances shown, you must do one

of the following:

• operate the logs only with the

flue damper open and damper

clamp installed

• raise the mantel to an ac-

ceptable height

• remove the mantel

FLOOR CLEARANCES

A. If installing appliance on the floor level, you

must maintain the minimum distance of 14"

to combustibles (see Figure 8).

B. If combustible materials are less than 14" to

the fireplace, you must install appliance at

least 5" above the combustible flooring (see

Figure 9).

14"

Min.

Combustible

Material

Noncombustible

Material

Hearth

5"

Min.

Combustible

Material

Figure 8 - Minimum Fireplace Clearances

If Installed at Floor Level

Figure 9 - Minimum Fireplace Clearances

Above Combustible Flooring

Minimum Non-
Combustible
Material

Minimum Non-
Combustible
Material Height

Distances to
Underside of
Mantel

Top of Fireplace
Opening

Underside of
Mantel Shelf

12"

(A)

28"

34

1

/

2

" 38

5

/

8

" 42"

All minimum
distances are
in inches

2

1

/

2

"

6"

8"

10"

Mantel Shelf

Minimum Non-
Combustible
Material

8"
Min.

14

1

/

2

" 18

5

/

8

" 22

1

/

2

"

All minimum
distances are
in inches

26"

2

1

/

2

"

6"

8"

10"

12"

Distances to
Underside of
Mantel

Hood
(GA6050,
GA6052
or GA6053)

Top of Fireplace
Opening

Underside of
Mantel Shelf

This manual is related to the following products: