SVS TMD User Manual
Page 7

should be your screen depth plus your screen mount depth plus 6-inches. With the Closure Adapter Kit
Accessory the minimum opening should be 26-inches wide by 12-inches deep. The Closure plate
extends 5-inches in front of the TMD column. If your combined screen and mount depth exceeds 5-
inches you will require an opening depth more than 12-inches.
•
See the TMD Closure Drawing in the Drawings and Schematics Section for details of closure
requirements for the screen you are using with the TMD lift. The closure for projector should be one
inch wider and deeper than the platform provided for the projector. You should consider extra space for
cable management. SVS recommends at least three inches.
6. Electrical Wiring and Lift Control
WARNING
DO NOT disconnect the telescoping column unit from the microprocessor control unit while the
telescoping column is at its end stops (fully extended or fully retracted).
Electrical Wiring
Step 1. Connect the microprocessor control unit to the telescoping column.
Using the supplied 1.0 Meter 8-pin cord, plug one end into the telescoping column. This
port is located at the lower right front of the column base. The other end connects to the
port labeled "M1" on the microprocessor control unit.
Step 2. Connect the 1.5 Meter two button control switch to the microprocessor control unit.
Using the supplied 1.5 Meter two button control switch, connect the 7-pin plug to the port
labeled "HS" on the microprocessor control unit.
Note: The two button switch wire can not exceed 2.5 Meters.
Step 3. Supply power to the microprocessor control unit.
Connect the power cord from the microprocessor control unit to a suitable 110 VAC outlet.
Step 4. The TMD Lift is now controllable with the two button control switch. Ensure that the TMD
lift will open to it full height and retract to it's closed position.
See TMD Wiring Drawing in Section 9.
Lift Control
The TMD Lift is normally controlled using the supplied two button switch. Pressing the UP arrow raises
the lift and pressing the DOWN arrow lowers the lift.
If your TMD Lift was ordered with the option to connect it to an external controller. Connect the white
wire to the red wire to raise the lift. For older TMD Lifts connect the white wire to green wire. Connect
the white wire to the black wire to lower the lift. The maximum wiring length from the microprocessor
control unit to the external control relay or switch can not exceed 6 foot. See External Wiring Options 1