On-off-on – SVS PLASMA TWO User Manual
Page 11
WHEN USING A TOUCH SCREEN CONTROLLER:
If an external controller is to be used (AMX, Crestron), please refer to the following wiring instructions
-see figure 8.
INSTRUCTIONS:
- Program a release of relays to stop on up and down positions.
- Program a time out after the normal run time, 1 or 2 seconds max.
1. Program an exclusive lockout on up and down so both positions cannot be activated at the same time.
2. Hold relays on to move the lift and release relays to stop the lift -always time out or release relay after
normal use. IMPORTANT: Never leave voltage on the up and down.
Always release voltage
immediately after the travel time has been achieved.
Wiring using Touch Screen Controller
(Figure 8).
IF USING ANY OTHER SYSTEMS, PLEASE CONTACT SVS FOR PROPER WIRING TO AVOID
UNSAFE OPERATIONS.
SVS PLASMA TWO LIFT INSTALLATION
Page 11 of 13
(SHOW)
93
+
-
(ON)
C
2
1
GRN
VIEW FROM BACK
BLK
ORN
BLK
WHT
MOTOR
POWER ON
80
ON-OFF-ON
77
RP2
WHT
24VAC
UP
DOWN
WHT
TOUCH SCREEN
RELAY TWO
TOUCH SCREEN
RELAY ONE
WHT
3
2
1
4
5
6
9
8
7
12
11
10