Introduction, Specifications – Super Systems Gold Probe User Manual
Page 3

2
SSi Gold Probe Manual Rev C
INTRODUCTION
Thank you for selecting the Gold Probe™ for your atmosphere control application.
The Gold Probe™ represents “state of the art” in carbon sensor technology. It has been
designed for use in carbon control systems as applied to both carbon control in
atmosphere furnaces and dew point in endothermic generators.
The Gold Probe™, with its unique measuring electrode construction, is the product of a
team of design and application engineers, each with over twenty years of atmosphere
control experience. The SSi engineering team has long recognized that the sensor is the
most critical component in the atmosphere control system and has traditionally been
the weakest link. Now, reliability, repeatability and accuracy are assured with the
inclusion of the Gold Probe™ in
your
control system.
SPECIFICATIONS
Useful %C Range- .01 to 1.6%
Temperature Range- 1200
F to 2000
F
(649
C to 1093
C)
Stability- within +/- 1 mVDC
Impedance- less than 10 kohms @ 1700
F
(927
C)
Mounting- 1" (25.4mm) NPT
Sheath dia.- 0.84" (1/2" pipe)
(21mm, 13mm pipe)
Useful output- 0 to 1250 mVDC
Probe Specifications
Model
Nominal Insertion
Length
Nominal Overall Length
Boxed Weight
INCHES
MILLIMETERS
INCHES
MILLIMETERS
POUNDS KILOGRAMS
GP133
14.3
364.0
20.8
528.0
3.6
1.8
GP205
20.5
521.5
27.2
690.0
4.0
1.8
GP277
27.7
705.0
34.3
871.0
4.6
2.1
GP330
33.0
840.0
39.5
1003.0
5.4
2.4
GP373
36.8
936.5
43.4
1101.5
5.8
2.6
GP420
42.0
1069.0
48.3
1228.0
6.4
2.9
GP480
48.0
1221.5
54.3
1379.5
6.8