Installation Instructions - Intergrated Application

Preparing the
Enclosure

Tools You Will
Need

Carpenter’s
Square

Measuring
Tape

Level

Drill & Hole Saw set

Gloves

Safety Glasses

Flashlight

It is recommended that you do
not install the wine cooler into a
corner (i.e. directly beside a
wall). This is to allow the door to
have a greater than 90° opening
swing. A limited door swing will
prevent the shelves from sliding
out as intended, and may lead to
damaging the door gasket.

The rough cabinet opening
must be on a level floor area
and at least 23

7/8

” (60.64cm)

deep* by 15” (38.1cm) wide.
The opening should also have a
height of at least 34

1/16

(86.52cm).

The electrical outlet may be
positioned from within either
side of the adjacent cabinetry, or
the rear of the shaded area (as
shown in Fig. D).

Important: If the electrical out-
let is surface mounted (not flush)
within the enclosure, the

depth

requirement for the installation
may be affected.

If the electrical outlet is located
inside the adjacent cabinetry, cut
a 1

1/2

” (3.81cm) diameter hole to

admit the power cord.

W A R N I N G !

While performing the
installations described in
this section; gloves, safety
glasses or goggles should
be worn.

Electrical Requirements

The appliance must be con-
nected to an individual and
properly grounded electrical
outlet, protected by a 15 or
20 ampere circuit breaker
or time delay fuse.

*The listed depth requirement for the installation is assuming that the electrical outlet is located in the
adjacent cabinetry or is flush mounted in the rear wall, not surface mounted in the enclosure.

IMPORTANT!

Door Swing

Do not include the door
within the enclosure; leave
it outside of the enclosure
to prevent the door swing
from being obstructed.

}

}

}

}

Fig D

1

3

4

2

6

Electrical

Access*

Fig D
1
23

7/8

” min. depth

2 34

1/16

” from under-

side of countertop
to floor.

3 15” min. width
4 2” of depth given

for Elec. Access*

5 1 1/2” dia. hole (if

outlet is in
adjacent cabinetry).

6 Cabinets square

and plumb