beautypg.com

Output power limit circuit (motor speed control) – Sun Pumps SCP 48-18-48Y BC User Manual

Page 18

background image



Output Power Limit Circuit (Motor Speed Control)


The Output Power Limit Control circuit is used to control the speed of the pump motor and thus the flow rate of
the pump. It is primarily used for low producing wells where the pump output is matched to the production rate of
the well. However it can also be used any time specific flow rates are required.

Output Power Limit Adjustment

The purpose of this procedure is to adjust the output power of the controller and thus reduce the water flow of the
pump. If tests have shown the pump will out produce the well capacity, then the controller “Speed Control”
feature can be used to match the flow rate of the pump to the production of the well.

1. With the system installed and controller properly configured, allow the pump to run at full power at mid-day

until the pump starts surging.


2. Slowly turn the “Speed Control” trim pot located on the face of the controller counter clockwise until the

pump stops surging. This is the point where the pump flow rate equals the well production. This process will
probably take a few attempts to “balance” the system for optimum water production. If maximum water is not
a critical issue you may want to reduce the pumps flow rate an additional 5% to 10% to insure the pump will
not run dry.

(NOTE: The trim pot has a15- turn range. It may take multiple complete turns in a counter-clockwise
direction before you will notice any change in water output or output power on the display).