Output power limit circuit (motor speed control) – Sun Pumps SCP 48-18-48Y BC User Manual
Page 18
Output Power Limit Circuit (Motor Speed Control)
The Output Power Limit Control circuit is used to control the speed of the pump motor and thus the flow rate of
the pump. It is primarily used for low producing wells where the pump output is matched to the production rate of
the well. However it can also be used any time specific flow rates are required.
Output Power Limit Adjustment
The purpose of this procedure is to adjust the output power of the controller and thus reduce the water flow of the
pump. If tests have shown the pump will out produce the well capacity, then the controller “Speed Control”
feature can be used to match the flow rate of the pump to the production of the well.
1. With the system installed and controller properly configured, allow the pump to run at full power at mid-day
until the pump starts surging.
2. Slowly turn the “Speed Control” trim pot located on the face of the controller counter clockwise until the
pump stops surging. This is the point where the pump flow rate equals the well production. This process will
probably take a few attempts to “balance” the system for optimum water production. If maximum water is not
a critical issue you may want to reduce the pumps flow rate an additional 5% to 10% to insure the pump will
not run dry.
(NOTE: The trim pot has a15- turn range. It may take multiple complete turns in a counter-clockwise
direction before you will notice any change in water output or output power on the display).
- SCP 100-60-180 BV SCP 115-60-240 BV SCP 50-50-120 BC SCP 58-51-48 BC SCP 62-42-105 BC SCP 67-50-120 BC SCP 75-40-105 BC SCP 80-55-180 BC SCP 86-55-180 BV SCP 86-65-180 BC SCP 94-37-120 BV MTR BLM-SB-103S-120Y MTR BLM-SB-203S-180 MTR BLM-SB-303S-240 PCC-120BLS-M2 PCC-180BLS-M2 PCC-240BLS-M2 MTR-BLM-SF-153C-120 MTR-BLM-SF-153C-90Y MTR-BLM-SF-303C-180 MTR-BLM-SF-353C-240 MTR-BLM-SF-153J-120 MTR-BLM-SF-153J-90Y MTR-BLM-SF-303J-180 MTR-BLM-SF-353J-240 PCA-120-BLS-M2 PCA-60-BLS-M2 MTR BLM-SB-073S-60 MTR BLM-SB-153S-120 SCS 10-165-60 BL SCS 10-600-240 BL SCS 14-95-60 BL SCS 18-90-60 BL SCS 7-210-60 BL