Figure 3 dip switch settings – Sun Pumps SCB-10-150-120 BL User Manual
Page 9
Figure 3 Dip Switch Settings
Switch
Switch
Description
Function
Default
Setting
Number
Position
1
OFF
Remote Switch Logic
Turns pump off when terminals
connect.
OFF
1
ON
Remote Switch Logic
Turns Pump on when terminals
connect.
OFF
2
OFF
Low Water Cutoff Logic
Turns pump off when terminals
connect.
OFF
2
ON
Low Water Cutoff Logic
Turns pump on when terminals
connect.
OFF
3
ON
10 Minute Delay
Increases turn on delay to 10
minutes
OFF
4
ON
30 Minute Delay
Increases turn on delay to 30
minutes
OFF
5,6
Not used at this time
Should be in the off position for
proper operation
OFF
7
ON
Display Freeze
Holds display on current screen
OFF
8
Not used at this time
Should be in the off position for
proper operation
OFF
This manual is related to the following products:
- SCB-10-150-180 BL SCB-10-200-180 BL SCB-10-220-180 BL SCB-10-265-180 BL SCB-21-350-240 BL SCB-22-165-120 BL SCB-22-185-180 BL SCB-22-250-180 BL SCB-22-95-120 BL SJT05-90BT SIJ 0.55-900P-90 BT SIJ 2.3-750P-150 BT SIJ 2.6-450P-90 BT SIJ 3.28-260P-75 BT SIJ 0.67-1500P-120 BL SIJ 2.2-1000P-105 BL SIJ 3.4-160P-45 BL SIJ 2.2-1300P-135 BL SIJ 2.9-700P-105 BL SIJ 3-640P-135 BL SIJ 3.1-220P-60 BL SIJ 3.1-700P-120 BL SJT10-120BL