3 pump installation – Sun Pumps SCB-10-150-120 BL User Manual
Page 6
3.3 Pump Installation
1. Write the pump, motor and controller model number and serial number in the space provided on the
last page in this Instruction Manual. This information will be needed when filling out the Warranty
Card. And will aide in any troubleshooting if necessary.
2. Inspect all components for shipping damage and insure that you have all the components that are
required for a complete installation.
3. Locate the pump on a flat surface close to the water source but do not mount in direct sunlight. The
motor requires free circulation of air so always install in a well-ventilated and dry area.
4. Keep the suction line as short and as direct as possible. This reduces the friction losses through the
pipe and fittings. The suction line should have continuous slope from the lowest point in the line to the
inlet of the pump. Make sure there are no loops or high spots in the suction line that could trap air.
5. Make sure the suction joints are tight. The suction line should be larger than the discharge pipe.
6. Connect the suction hose and foot valve or check valve to the suction port of the pump. Barbed type
connectors should always be double clamped. For poly pipe, compression fittings are recommended.
7. Connect the discharge pipe to the pipeline or pressure system as required.
Figure 1 Typical Pressure System Using A Pressure Tank
- SCB-10-150-180 BL SCB-10-200-180 BL SCB-10-220-180 BL SCB-10-265-180 BL SCB-21-350-240 BL SCB-22-165-120 BL SCB-22-185-180 BL SCB-22-250-180 BL SCB-22-95-120 BL SJT05-90BT SIJ 0.55-900P-90 BT SIJ 2.3-750P-150 BT SIJ 2.6-450P-90 BT SIJ 3.28-260P-75 BT SIJ 0.67-1500P-120 BL SIJ 2.2-1000P-105 BL SIJ 3.4-160P-45 BL SIJ 2.2-1300P-135 BL SIJ 2.9-700P-105 BL SIJ 3-640P-135 BL SIJ 3.1-220P-60 BL SIJ 3.1-700P-120 BL SJT10-120BL