beautypg.com

Sun Pumps SCP 39-18-75 LC User Manual

Page 10

background image

1. Turn off motor.

2. Relieve pressure in the system.

3. Turn the lid in a counter-clockwise direction until it stops.

4. Lift lid and remove basket.

5. put the debris from the basket into the trash and rinse out
basket. if the basket is cracked it should be replaced.

6. Replace the basket and fill the pump pot and volute with water.

7. Clean the cover, O-ring and sealing surface of the pump pot.
Grease the O-ring with Teflon or silicone.

8. Reinstall the strainer lid.

9. Make sure the lid O-ring is properly placed. Seat the lid then turn
clockwise until hand tight. DO NOT over tighten with tools.

10. Turn the power “ON” at the main disconnect or circuit breaker.

11. Open the manual air relief valve on top of the filter.

12. Stand clear of the filter. Start the pump.

13. Bleed air from the filter until a steady stream of water comes
out. Then close the main air relief valve.

TO AVOID POTENTIAL HAZARDS, FOLLOW THESE INSTRUCTIONS
FOR CLEANING THE BASKET STRAINER.

4009458

Conforms to UL Stds 1081 & 1563