Figure 4 dip switch settings – Sun Pumps MTR BLM-SB-073S-60 User Manual
Page 13
Figure 4
Dip Switch Settings
Switch
Switch
Description
Function
Default Setting
Number
Position
1
OFF
Remote Switch Logic
Turns pump off when terminals connect.
OFF
1
ON
Remote Switch Logic
Turns Pump on when terminals connect.
OFF
2
OFF
Low Water Cutoff Logic
Turns pump off when terminals connect.
OFF
2
ON
Low Water Cutoff Logic
Turns pump on when terminals connect.
OFF
3
ON
10 Minute Delay
Increases turn on delay to 10 minutes
OFF
4
ON
30 Minute Delay
Increases turn on delay to 30 minutes
OFF
5,6,7,8
OFF
Not used at this time
Must be in the off position for proper
operation
OFF
This manual is related to the following products:
- MTR BLM-SB-153S-120 SCS 10-165-60 BL SCS 10-600-240 BL SCS 14-95-60 BL SCS 18-90-60 BL SCS 7-210-60 BL PCA-120-BLS-M2 PCA-60-BLS-M2 SCP 100-60-180 BV SCP 115-60-240 BV SCP 50-50-120 BC SCP 58-51-48 BC SCP 62-42-105 BC SCP 67-50-120 BC SCP 75-40-105 BC SCP 80-55-180 BC SCP 86-55-180 BV SCP 86-65-180 BC SCP 94-37-120 BV MTR BLM-SB-103S-120Y MTR BLM-SB-203S-180 MTR BLM-SB-303S-240 PCC-120BLS-M2 PCC-180BLS-M2 PCC-240BLS-M2 MTR-BLM-SF-153C-120 MTR-BLM-SF-153C-90Y MTR-BLM-SF-303C-180 MTR-BLM-SF-353C-240 MTR-BLM-SF-153J-120 MTR-BLM-SF-153J-90Y MTR-BLM-SF-303J-180 MTR-BLM-SF-353J-240 PCA-120-BLS-M2S PCA-60-BLS-M2S