Model 79 configuration—restore factory defaults – Studio Technologies 78 2004 User Manual
Page 26

Issue 5, January 2004
Model 78/79 User Guide
Page 26
Studio Technologies, Inc.
for Surround
Press and hold both the 5.1 and Mono buttons for 5 seconds to restore
Model 79 factory defaults. Once defaults have been restored, the LEDs
will light. After the buttons are released, configuration mode will be
exited and normal operation will resume.
Model 79 Configuration—Restore Factory Defaults
Factory Defaults: All channels associated with both inputs are active.
Additive solo mode enabled.
Upon power up, mute all function enabled.
Level control operates modified logarithmic.
Output level offset view only.
Level control auto mute all function enabled.
Output level range mode 1, –70 to 0 dB.
Reference level is set for fully attenuated (minimum) monitor output level.
20 dB dim level.
Remote mute all disabled.
Remote dim disabled.
Downmix stereo set to mode 1.
Downmix mono set to mode 1.
Remote input select function disabled.
Surround A associated with remote input select function.
Output level offset 0 dB for all channels.
Note:
The 5-second delay is a safety feature, ensuring that the factory defaults will not be accidently
restored.