Studio Technologies 55 1996 User Manual
Page 41

Model 55/56 User Guide
Issue 3, December 1996
Studio Technologies, Inc.
Page 41
Function: Control Room Output Select
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
02H
Product ID (Model 55)
6
09H
Function: Control Room Output Select
7
nnH
Output Selected, Range 00-11:
L Ch.
R Ch.
Action
0
0
No Output
1
0
Left Only
0
1
Right Only
1
1
Left and Right
8
F7H
EOX, End of System Exclusive
Function: Control Room Mono/Stereo Select
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
02H
Product ID (Model 55)
6
0AH
Function: Control Room Mono
7
0nH
Output Selected, Range 0-1, 0=stereo, 1=mono
8
F7H
EOX, End of System Exclusive
Function: Control Room Dim
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
02H
Product ID (Model 55)
6
0BH
Function: Control Room Dim
7
0nH
Status, Range 0-1, 0=No Dim, 1=Dim
8
F7H
EOX, End of System Exclusive