To ensure the best motor control match, advanced motor control CVs 209 –

214 have been set to the following default values.

Table C. TSU-IM1000 Default Lighting Outputs

Hyperlight

CV

EMD 567

EMD 645

Turbo

GE GEVO-12

Pin 1

51

Mars Light

Number Board

Number Board

Pin 2

49

Headlight

Headlight

Headlight

Pin 3

50

Number Board

Backup Light

Backup Light

Pin 4

52

Side Lights

Ditch Lights

R Ditch Light

Pin 5

N/A

+ Common

+ Common

+ Common

Pin 6

53

-

-

L Ditch Light

Table D. TSU-IM1000 Advanced Motor Control Default Values

CV

EMD 645 Turbo

GE GEVO-12

Description

EMD 567

209

Kp Coefficient

30

25

210

Ki Coefficient

25

25

212

Motor Control Intensity

255

255

213

Motor Control Sample Period

24

24

214

Motor Control Sample Aperture Time

7

7

Bit 7

Bit 0

FX6B.R FX6B.F FX6A.R FX6A.F FX5B.R FX5B.F FX5A.R FX5A.F

Bit 7

Bit 0

FX6OVR FX5OVR