beautypg.com

Theory of operation, Product identification, General safety information (continued) – Dayton 3VH19A User Manual

Page 3

background image

Version B - For Reduction

G016.J

®

3

Model 3VH18A - Propane
Model 3VH19A - Natural Gas

Dayton Operating Instructions and Parts Manual

HIGH

MEDIUM

Theory of Operation

Figure 2 - Product Identification

Product Identification

THE FUEL SYSTEM

Propane Model: The hose/regulator
assembly attaches to the propane gas
supply. This provides fuel to the heater.

Natural Gas Model: The gas supply
attaches to the heater by a minimum 3/4
inch i.d. hose or flexible connector. User
must supply hose or flexible connector.
The length should be no more than 10
feet long. The natural gas moves through
the regulator and out the nozzle.

THE IGNITION SYSTEM

The piezo ignitor lights the main burner.

THE AUTOMATIC CONTROL SYSTEM

This system causes the heater to shut
down if the flame goes out.

General Safety Information
(Continued)

• Never move, handle, or service a hot

or operating heater. Severe burns
may result. You must wait 20
minutes after turning heater off.

• To prevent injury, wear gloves when

handling heater.

• Never attach duct work to heater.

• Do not alter heater. Keep heater in

its original state.

• Do not use heater if altered.

• Turn off gas supply to heater when

not in use.

• Use only original replacement parts.

This heater must use design-specific
parts. Do not substitute or use
generic parts. Improper replacement
parts could cause serious or fatal
injuries.

Piezo Ignitor Button

Valve
Inlet

Shell

Base

Control
Knob

Hose/Regulator
Assembly for
Propane Gas

Ignitor
Electrode

Burner
Tube

Thermocouple

Top

Base
Shield

Upper Shield

Lower Shield

Emitter

Regulator for
Natural Gas

This manual is related to the following products: