Operation, Troubleshooting – Smithco Envizio Pro Quick Reference Guide User Manual
Page 16

1 5
Operation
During a job, the AutoBoom Status Indicator will be displayed on the
Guidance
screen.
This area may display the following indicators for the current status of the
AutoBoom system:
Status of the center rack is only displayed if a Glide Series AutoBoom system
capable of controlling the center section is connected to the field computer. Touch
the displayed status icon to access the
Glide Series AutoBoom Calibration
screen.
Troubleshooting
The following are a few general tips for troubleshooting the product control
system. Refer to the Envizio Pro and Envizio Pro II Installation and Operation
manual for detailed troubleshooting information.
Issue
Possible Cause
Solution
CANbus cannot
read Node(s)
• CANbus ends
not terminated
• Make sure that both ends of the CANbus
system are properly terminated. Refer to
the Raven CANbus Network Installation
Manual for more information.
• Corroded pins
in CANbus
connections
• Check CANbus cable connectors for any
highly corroded pins.
• Ensure dielectric grease has been
applied to all cable connections exposed
to weather and field conditions.
• Moisture in
connection
• Check CANbus cable connectors for any
corroded pins.
• Ensure dielectric grease has been
applied to all cable connections exposed
to weather and field conditions.
• Connectors
not seated
properly
• Check that all CANbus cable connectors
are inserted fully (until the locking tab is
engaged).
• Be sure to remove any moisture in
connections which were not properly
seated. Check for corroded pins and
apply dielectric grease when
reconnecting CANbus cables.
Disabled
Off
Left/Right
Enabled
Both
Enabled
or
Center Rack
Enabled