beautypg.com

Basic troubleshooting – Smithco V-Star 94-201 (Sn V192) Operator Manual User Manual

Page 15

background image

15

BASIC TROUBLESHOOTING



Unit will not move:

1. Check the neutral knob located on the left side of the unit to make sure that it is

not in the “N” position.

2. Check the control lever to ensure that cable is not broken.
3. Check key in axle hub for loss or broken key.
4. Check control arm on transaxle.
5. Check cable clevis pins.
6. Make sure that there are no oil leaks on the transaxle.
7. Make sure all belts are in place.


Unit will not start:

1. Check all wiring.
2. Check voltage of battery.
3. Test key switch.
4. Check

solenoid.

5. Check spark plug for proper gap.
6. Check

starter.


Unit will not raise or lower blades:

1. Check all wiring.
2. Check circuit breaker located by positive battery terminal.
3. Check actuator switch.
4. Check voltage of battery.
5. Check

actuator.


Blades will not stop turning when shut off:

1. Check to make sure that clutch is fully disengaged.
2. Check that belt brake is adjusted properly with 1/8” clearance at the bottom of belts.
3. Check to make sure that belt guide bolt is in place.
4. Make sure belts are not damaged.


Blades will not turn when lowered into the turf:

1. Make sure belts are tightened properly.
2. Check clutch control cable for breaks or missing clevis pins.
3. Check for debris in blade area.