beautypg.com

Error codes – Skutt GlazeTech 8/2013 User Manual

Page 10

background image

10

10

e

rror

c

odeS

ERROR CODES

tC FaIL tC alternating with FaIL indicates the thermocouple has failed. replace the defective thermocouple. To clear
the error, press any key.

errP errP is displayed whenever there is a power interruption that is long enough to stop the firing. If the power
interruption is brief the kiln will continue to fire when power is restored; in this case there will no indication of a
power failure. To clear the error, press any key.

tC- - The red and yellow thermocouple wires are reversed.

Messages
CPLt

Firing Cycle Complete (firing time is alternately displayed).

deLa delay. displays when entering the delay time (hour:minutes) until the start of the firing.
dLy

delay. alternates with the remaining delay time until the start of the kiln.

°F #

segment temperature in °F – set temperature for a user program.

°C # segment temperature in °C – set temperature for a user program. a decimal point will display in lower right
corner.
edIt

edit the default options (beeping at complete, temperature scale, cone fire, delay, maximum programmable

temperature)
errP

There has been a power interruption that has stopped the firing. Press any key to clear.

FuLL

Beeps continuously at end of firing until a key is pressed.

hLd# soak time in hours:minutes at a hold temperature.
oFF

no beeping when firing is complete.

on

Beeps for 15 seconds at end of firing.

ra # ramp number (rate per hour of temperature increase or decrease).
redl ready to fire current program. Press sTarT to begin firing.
seG

short for segments. You can enter up to 8 segments in a program.

sstP

skip step (used to advance to the next ramp)

stoP The kiln is at idle and ready to be programmed. stop alternates with the current kiln temperature.
usr # user program number displayed