1. Introduction

This document describes the control program software for the Sierra Video Systems SmartLinx Bus Adapter,

a.k.a. SmartLinx Host Adapter.

Additional documents should be referred to for complete information:

Circuit schematics for the control processor board.

Bus Adapter Processor Board C Runtime Support Code document.

SmartLinx protocol document.

68302 Processor C Function Library document.

68000 Processor Library document.

General-Purpose C Function Library document.

Motorola 68302 processor handbook.

Sierra Systems C Compiler Manual

2. DIP and Rotary Switch Settings

This section describes DIP and Rotary switch settings.

2.1 DIP Switch S6

Figure 1: DIP Switches

1

2

3

4

5

6

7

8

Off On

(0) (1)

Sw 1: Fast Acquire Mode:

0 = 15 seconds to poll all non-responding devices

1 = 5 seconds to poll all non-responding devices

Sw 2: Disconnect Tolerance: 0 = Disconnect after one failure to respond to a poll

1 = Disconnect after four consecutive poll response failures

Sw 3: Flow Control:

0 = Hardware flow control (CTS/RTS)

(affects both ports) 1 = Software flow control

Sw 4: Poller Enable:

0 = Bus adapter not enabled for polling

1 = Bus adapter is enabled for polling



Sw 65: Host Port B Speed:

00 = 9600 bps; 01 = 38,400 bps; 10 = 115,200 bps; 11 = 230,400 bps

Sw 87: Host Port A Speed:

00 = 9600 bps; 01 = 38,400 bps; 10 = 115,200 bps; 11 = 230,400 bps

Any DIP switch change results in an immediate automatic
reset.