beautypg.com

Ddress – Sierra Video 507125 User Manual

Page 12

background image

Sierra Video Systems

SmartLinx Bus Adapter

busadap.doc

12

CmdChar Direction

Description

C

(Connect)

Poller

All

A connection to some SmartLinx device has been established by the poller.

D

(Disconnect)

Poller

All

The poller has lost the connection to some SmartLinx device. Any mutexes that
have been allocated by the device are automatically released.

F

(FrameID)

Poller

All

Every 200 ms the poller sends this message to all devices to allow those in a
particular frame slot to use the frame ID lines to determine which frame they are in.

H

(High Speed)

Any

Poller

A SmartLinx device requests a temporary change in the EIA-485 bus data rate. The
poller sends an “h“ message in response.

h

(High Speed)

Poller

Any/All

Sent in response to receiving an “H“ message. If the “H“ message request is
denied, this message is sent only to the sender of the “H“ message. Otherwise, it is
sent to all devices to announces the beginning of a temporary change in the EIA-485
bus data rate.

L

(Loopback)

Any

Poller

Loopback send diagnostic message, poller sends data back to sender using “l”
message.

l

(Loopback)

Poller

Any

Loopback reply diagnostic message, sent in response to receiving an “L“ message.

N

(Name)

Any

Poller

Queries for the poller’s module name. The poller sends an “n” message in
response.

n

(Name)

Poller

Any

The poller reports its name in response to receiving an “N” message. The name is
fixed as “Poller”.

P

(Poll Params)

Any

Poller

Changes a SmartLinx module’s polling parameters, or queries for them. The poller
sends a “p” message in response.

p

(Poll Params)

Poller

Any

The poller reports a SmartLinx module’s polling parameters in response to receiving
a “P” message.

Q

(Query)

Any

Poller

Queries for which devices are connected. The poller sends a “q” message in
response.

q

(Query)

Poller

Any

The poller reports which devices are currently connected in response to receiving a
“Q” message.

R

(Reset)

Any

Poller

The poller and its Bus Adapter reset themselves as if just powered up after receiving
this message.

r

(Reset)

Poller

All

The poller sends this message at startup to announce that it has just started up.

W

(Which)

Any

Poller

Request for the poller to send a “w” message reporting the message bytes it
understands and/or sends.

w

(Which)

Poller

Any

The poller reports the message bytes it understands and/or sends, in
response to receiving a “W” message.

X

(eXclusion)

Any

Poller

Request for the poller to allocate or release a mutual exclusion semaphore. The
poller sends an “x” message in response.

x

(eXclusion)

Poller

Any/All

The poller reports a change in ownership of a mutual exclusion semaphore in
response to receiving an “X” message. If the “X” message request failed, this
message is sent to the sender of the “X” message. If ownership of a mutal
exclusion semaphore actually changed, this message is sent to all devices.

Table 5: Universal Messages Understood or Sent by Poller-Enabled Bus Adapters at the Poller Address

The End