Stream Control

Stream control window allows individual network configuration and control of one of
the two streams.

The “Current” section displays the stream status and allows starting and stopping the
stream.

The “Settings” section configures the following stream parameters:

Protocol: currently only UDP is supported.

Destination: an IP address of the destination host.

Port: network port of the destination host.

Retry timeout: determines the length of time (in seconds) during which the 2453 tries to
obtain destination's ARP entry.

Sequencing: if on, a 2 byte sequence counter is sent with each packet. That could be used
by the software on the receiving end to detect network packet loss.

Startup: if set to On, the stream will start automatically when the 2453 is powered up.