Sea Eagle Sailcat 14 (2013 and earlier) User Manual
Page 4
Included are a cluster of seven valve adapters.
Raised numbers are located on each arm of
the cluster. The only adapter needed for your
Sea Eagle is adapter number 1.
Also included is the same triple nozzle adapter
as your A-41 foot pump. Using the large
rounded nozzle take the ribbed end and insert
into the hose of the MB-100.
Remove adapter number 1 and push firmly
into the large rounded nozzle. To ensure that
the adapter is on as tight as possible, push it
against a hard surface like a floor or table
once it is connected to the nozzle.
Locate the red joint piece and attach the
ribbed end into the other end of the hose.
Once the joint is attached to the hose, push
into the inflation port. Directly located above
the pressure dial the inflation port can easily
be identified by the raised arrows on the red
pump cover which point to it.
Adjust the pressure dial to read 3.2 PSI which
is the operating pressure for your Sea Eagle.
Connect the power supply to a 12V battery
(car or marine battery) using the alligator clips
at the end of the extension cord. Connect the
red to the positive pole and the black to the
negative pole.
When you are ready to inflate switch the pump
on with the ON-OFF switch. The MB-100 will
automatically stop once the set pressure is
reached. You will still need to switch the pump
off when you are finished.
Turbo Electric Pump (Optional)
The Turbo Electric Pump comes complete with
a nylon shoulder carry bag, 12V DC power
supply, hose and various adapters.
Included are a cluster of seven valve adapters.
Raised numbers are located on each arm of
the cluster. The only adapter needed for your
Sea Eagle is adapter number 1.
Remove adapter number 1 and push it firmly
into the joint (grey tube) that is already con-
nected to the end of the hose.
The gray tube must be pushed past the raised
ring inside the adapter. Strike it against a hard
surface like a floor or table until you feel it
click. Wetting the adapter with water will help it
slide easier.f
Screw the other end of the hose into the red
inflation port which is located near the ON and
OFF buttons.
Adjust the pressure dial to 3.2 PSI which is the
operating pressure for your Sea Eagle. PSI is
marked in red on the dial.
NOTE: When the device is under pressure,
never turn the dial on the manometer
counter-clockwise as this would immedi-
ately cause the instrument to break.
Connect the cord at the end of the power sup-
ply into the end of the cord attached to the
pump.
3