beautypg.com

Hd356, Utility connections – Scotsman HD356 User Manual

Page 6

background image

Utility Connections

As ice melts in the dispenser the water must be
drained away. It is critical that a proper drain be
connected to the dispenser. Remember that this is
a gravity drain system - tubing must slope down a
minimum of ¼" per foot of horizontal run.

Follow all applicable codes.

Usually an air gap must be established between
the end of the drain tube and the building’s drain
receptacle.

The dispenser’s drain must be separate from
the drain used by the ice
machine.

Use only rigid tubing.

Install a vent at the ice
machine’s reservoir
drain AND the
dispenser’s drain.
Failure to vent the
drains may result in
water backup.

Electrical:

There is a junction box on the back of the machine,
connect the power supply to the wires inside the
junction box.

Follow all applicable codes.

Be certain that the ice machine AND dispenser are
grounded.

Electrical Power

Supply

Ice Machine Drain -

VENT REQUIRED

Dispenser Drain

DO NOT CONNECT

TOGETHER WITH ICE

MACHINE DRAIN

Dispenser

Electrical

Junction Box

HD356

June 1998

Page 6