beautypg.com

Warning, Troubleshooting, Problem possible cause possible solution – Royal Vacuums UR30090 User Manual

Page 26

background image

13

PROBLEM

POSSIBLE CAUSE

POSSIBLE SOLUTION

Vacuum won’t

run

1. Power cord not firmly plugged

into outlet.

1. Plug unit in firmly.

2. No voltage in wall plug.

2. Check fuse or breaker in home.

3. Blown fuse or tripped breaker.

3. Check fuse or breaker in home. Replace

fuse/reset breaker in home.

4. Thermal Protector activated.

4. Unplug and allow vacuum to cool for 30min.

(This willl reset the thermal protector)

Bag Check

Indicator has

turned red

or

Vacuum won’t

pick up

or

Low suction

1. Filter Bag full and/ or clogged.

1. Replace Filter Bag - Pg. 9.

2. Broken or worn belt.

2. Replace belt - Pg.12.

3. Brushroll and/ or Hose

clogged.

3. Check Brushroll - Pg.10.Check Hose - Pg.11.

4. Carpet height setting is

incorrect.

4. Set Carpet Height Adjustment to appropriate

setting for carpet being cleaned - Pg.7.

5. Suction Only Mode is ON.

5. Step on Brushroll ON/OFF Pedal to turn

Suction Only Mode OFF- Pg. 6.

Dust escaping

from vacuum

1. Filter Bag full.

1. Replace Filter Bag - Pg. 9.

2. Filter Bag not installed

correctly.

2. Review Filter Bag removal & replacement

- Pg. 9.

3. Hose not installed correctly.

3. Review Hose installation - Pg. 8.

Headlight not

working

1. Bulb burnt out.

1. Replace bulb - Pg. 11.

2. Loose electrical wires.

2. Call 1-800-321-1134 for nearest authorized

Royal

®

dealer.

Vacuum is

difficult to push

or won’t move

forward

1. Carpet height setting is

incorrect.

1. Set Carpet Height Adjustment knob to

appropriate setting for carpet being cleaned

- Pg. 7.

2. Bottom plate is not installed

correctly.

2. Refer to Fig. 4.22 - Pg. 12.

3. Brushroll is activated.

3. For very high pile carpet deeper than 1”,

turn brushroll off.

Air - Powered

Hand Tool

brushroll won’t

turn

1. Too much pressure being

applied to tool.

1. Continue using tool applying light pressure.

2. Blockage.

2. Remove blockage - Pg. 11.

3. Low vacuum suction.

3. Check items under “Vacuum won’t pick or

Low suction.”

Smoky/burning

smell detected

1. Belt broken or stretched.

1. Replace brushroll belt - Pg. 10.

2. Brushroll is clogged.

2. Clear/ remove debris from brushroll - Pg. 10.

5. TROUBLESHOOTING

If a minor problem occurs, it usually can be solved quite easily when the cause is found by using the

checklist below.

Any other servicing should be done by an authorized service representative.

If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water,

take it to a service center prior to continuing use.

WARNING

!

!

To reduce risk of personal injury - unplug vacuum before servicing.

This manual is related to the following products: