Fig. 14, Fig. 12, Fig. 13 – Royal Cozyfires Super Hotbox Toaster MK4 - LPG User Manual
Page 10
10
HM83 010710
2.4.2
INSTALLING THE APPLIANCE (Clearance to sides and shelves) Super Hot Toaster Mk4
The minimum clearance to any combustible material to the side of the appliance must be 150mm (Fig. 12).
The minimum clearance to any non-combustible material around the perimeter of the appliance must be 75mm.
The minimal clearance to the underside of a 150mm depth combustible shelf from the hearth must be 790mm. Add 12.5mm to this
clearance for every 25mm increased depth of shelf (Fig 12). A `SHELF CHART’ (Fig 13) is provided to aid in calculating shelf clearances.
2.4.3
INSTALLING THE APPLIANCE (Hearth clearances)
A non-combustible hearth with a minimum thickness of 12.5mm and having a perimeter of 50mm above floor level is required to discourage
placing carpets or combustible materials close to the hearth. The width must be a minimum of 150mm either side of the fireplace opening
and a depth of 300mm from the front face of the fire opening (Fig 14).
FIRE
OPENING
HEARTH AREA
150mm
300mm
Fig. 14
Minimum hearth height - 50mm
Minimum hearth width - 805mm
Minimum hearth thickness - 12.5mm
790mm
150mm
Add 12.5mm to clearance for every
25mm increased depth of shelf
Fig. 12
802.5
815
827.5
840
852.5
175 200 225
250
275
SHELF CHART
Shelf Depth 150
All dimensions are in MM
Shelf Height 790
Fig. 13