Installation – REMKO AMT 40E User Manual

Page 9

background image

Electrical connection

The equipment is

operated at
230 V/50 Hz AC.

Electrical connection takes place

via a fitted mains cable with
earthing pin plug.

Extension of the connecting

cable may only take place by
authorised electricians, taking
into account the cable length,
unit installed load and local use.

Installation

For economical and reliable unit
operation, the following infor-
mation must be followed in any
event:

The units must be installed sta-
ble and horizontal to ensure un-
hindered condensate discharge

The units must be installed in

the centre of the room if pos-
sible, so that optimal air circula-
tion is ensured

It must be ensured that air is

able to be sucked in freely at
front of the unit and blown out
freely at the rear of the unit

A minimum distance of 50 cm

to walls must be maintained

The units should not be installed

in the immediate vicinity of
radiators or other heat sources

Room air circulation can be

improved by installing the units
raised about 1 metre

The room to be dried or dehu-

midified must be closed with
respect to the ambient atmos-
phere

Open windows, doors, etc.

as well as frequent entering
and leaving the room must be
avoided as far as possible

If the units are used in dust-lad-

en environments or in stables,
care and maintenance measures
specially adapted to the particu-
lar conditions must be taken

The unit capacity is solely

dependent upon the spatial con-
ditions, room temperature, rela-
tive humidity and observance of
the installation instructions

CAUTION

All cable extensions may be
used only when unrolled.

NOTE

Electrical connection must take
place to supply points with
residual-current protective
unit according to
VDE 0100, part 704.
For installation of the units
in damp areas such as utility
rooms, shower rooms or simi-
lar, the units must be protected
with a residual-current-oper-
ated circuit-breaker complying
with the requirements.

Distance to walls
minimum 0.5 m

Maintain distance to radiators or

other heat sources.

Keep windows and doors closed!

9