Putting out of service, Important hints, Fault elimination hints – REMKO PGM 100 User Manual
Page 5

5
Close all the bottle valves.
 
Let flame burn out. 
 
The fan should still run for a few se-
conds to exhaust the accumulated 
heat. 
Putting out of Service
Put operating switch into “0” position (= 
off) and unplug mains plug from the 
mains socket. 
Hint PGT 100
The unit has been equipped with an automatic fan af-
ter-running phase to avoid heat accumulation and 
consequently the release of STB when the burner has 
been switched off. 
 
Therefore the electric connection to the mains may not 
be interrupted (with the exception of emergency situa-
tions) before the post-cooling time has lapsed! 
Put operating switch into “II” position. In this 
position only the ingoing air fan runs and the 
unit can be used for air circulation. 
Ventilation
Important!
 
Make sure to place gas reservoir only laterally behind 
the unit! Never heat up or defrost gas reservoir through 
the unit’s hot air current (danger of explosion!). 
 
Never use gas reservoir in a lying position when the unit 
is operating (gas leakage in the liquid phase). 
Important Hints
 
Assembly of Multi-bottle Set
 
To avoid intensive icing of the gas bottle during a longer 
operation of the unit, we recommend that you use a 
bottle battery consisting of at least 3 bottles. All bottle 
valves must be open to ensure regular gas supply! 
T-connection
high pressure hose 0.4 m
pressure controller
hose-break protection
gas hose to unit
When the fault-indicating lamp of 
the automatic burner relay is lit 
up, the reason for the fault has to 
be detected and to be eliminated 
first. 
Release is carried out by pressing 
the fault-button. 
It is not possible to unlock the automatic burner relay 
immediately after releasing. 
 
M a k e s u r e t o o b s e r v e w a i t i n g t i m e o f a p p r ox . 
6 0 s e c o n d s ! 
 
You will find a detailed chart for the fault 
elimination in chapter “Action in the case of faults”. 
2. Automatic Burner Relay
“RESETTING” is not possible before the sensor has 
cooled down below approx. 90 °C. 
Fault Elimination Hints
 
1. Safety Temperature Limiter 
 
The safety temperature limiter (STB) interrupts gas 
supply in the case of overheating and the unit is locked 
on the electric side. Any unit function is switched off. 
 
When the safety temperature limiter has released, the 
reason for the fault is to be detected and to be elimina-
ted first. Unlocking is carried out when the protective 
cap has been unscrewed by pressing the key “STB-
RESET“. 
- remove protective cap (1)
 
- press key (2) 
 
- refit protective cap (1) 
Clean gas supply line thoroughly before starting the unit for the first time!
1
2