beautypg.com

Technical data – REMKO PGM 100 User Manual

Page 15

background image

15

Series PGT 30 PGT 60 PGT 100

Nominal heat output kW 26 55 100

Heating capacity kW 10 – 26 25 – 55 50 – 100

Air output m³/h 800 1.450 3600

Fuel/type of gas l i q u i f i e d g a s C a t. I

3 B / P

Unit connecting gas-pressure bar 1,5 1,5 1,5

Unit connecting value kg/h 0,78 – 2,0 1,95 – 4,27 3,9 – 7,8

Electrical connection 1~ V 230 230 230

Frequency Hz 50 50 50

Power consumption kW 0,07 0,11 0,125

Fuse-protection (required) A 10 10 10

Kind of protection IP 44 IP 44 IP 44

Sound pressure level L

pA

1m

1)

dB(A) 56 – 69 62 – 72 74 – 82

Weight (without accessories) kg 12 20 47

Dimensions Length mm 450 650 1060

Width mm 260 320 435

Hight mm 410 510 620

1) Noise measuring DIN 45635 - 01- KL 3

Technical Data

Automatic burner relay: Working voltage 230 V (-15% + 10%)

Frequency 50 Hz (40 - 60 Hz)

Safety time 5 seconds

Waiting time after interference cut-off ca. 60 seconds

Allowable ambient temperature – 20° C ... + 60° C

Min. required ionisation current 5 µA

Sensitivity (ionisation current) 1 µA

Kind of protection IP 44

Any operation/handling which does not correspond to that indicated in these instructions is prohibited,

otherwise we will not be responsible and the guarantee will become void.

The orderer or the customer must have properly filled out the “guarantee certificate” which is enclosed

with every REMKO automatic heater and must have returned it to REMKO GMBH & Co. KG within

a timely acceptable period based on the sale and commissioning, to be entitled to possible

guarantee claims regarding faulty material.

Technical Data: