Wiring diagram technical data, Service and guarantee – REMKO PG 12E User Manual

Page 9

background image

9

1~

L1

1

2

3

4

1

2

3

4

KL

MV2

M

BS

Z

PZ

TE

MV1

TB

N

PE

Wiring Diagram

Technical Data

KL = terminal strip

M = fan motor

TE = thermocouple

BS = operating switch

Z = ignition electrode

MV1 = gas valve (thermoelectric)

MV2 = gas valve (electromagnetic)

PZ = piezo electric igniter

TB = temperature limiter

Series

PGM 12/12 E

Nominal heat output

kW

12

Heating capacity

kW

12

Air output

m³/h

250

Fuel/type of gas

liquid gas

Cat. I

3B/P

Gas pressure

mbar

300

Gas consumption

kg/h

0,95

Electrical connection

V

230

Frequency

Hz

50

Power consumption max.

W

60

Fuse protection

A

10

Kind of protection

IP

44

Sound pressure level L

pA

1m

1)

dB(A)

57

Weight

kg

6,8

Dimensions total length

mm

400

width

mm

185

height

mm

320

1)

noise measuring DIN 45635-01-Kl3 in heating operation

Correct usage

The units are to be used only for heating and ventilation
purpose in industrial or commercial application because
of their construction and equipment.

If specification of the manufacturer or legal regulations,
are not followed or if unauthorised changes are made
on the unit, the manufacturer is not liable for resulting
damages.

An operation/use other than that indicated in these
instructions is prohibited!
In the case of non-observation we will not be held
responsible and our guarantee will become void.

Service and Guarantee


Any claims under guarantee regarding materials can be
accepted only when the orderer or his customer has
filled in completely the “guarantee certificate” which is
enclosed with every REMKO-heater and has returned it
to REMKO GmbH & Co. KG in due time after the unit’s
sale and commissioning.

The units are factory tested on faultless function. If any
failure occurs though which cannot be eliminated by the
operating person, please contact your dealer or contact
person.