beautypg.com

Maintenance – REMKO PG 12E User Manual

Page 8

background image

8

Disassembly for Cleaning

2

3. Remove three fasten-

ing screws 2 of air
suction grille.

4. Remove air suction

grille with fan motor
and fan blade

5. Pull the inner casing

to the front.

Cleaning the unit

After disassembly all components are easily accessible
for cleaning and maintenance purposes.

Clean burner carefully.
Possibly use compressed air.

Clean gas nozzle carefully when necessary.

Carefully remove dirt and dust from ignition elec-
trode, thermocouple and temperature limiter.

Remove deposits and other dirt from base of unit.

Assemble all the parts thoroughly in reverse order.

ignition
electrode

thermo-
couple

3

mm

temperature limiter

gasburner

Maintenance


Depending on the operation conditions the units are to
be tested by an expert when necessary, but at least
regularly every two years, to ensure their safe operation.

The test result is to be recorded in a test certificate
which is to be safely kept until the next test so that it can
be presented to the authorised persons for control pur-
poses at any time.

Regular maintenance and care, at least after each heat-
ing period is the basic condition for a long service life
and a faultless operation of the unit.

Setting and maintenance is to be carried out only
by authorised experts!

Please pay attention to the following points:

The unit is to be maintained and cleaned in regular
intervals.

The unit is to be kept free from dust and other de-
posits and is to be cleaned only with a dry or humid
cloth.
Do not use water jet.

Do not use any aggressive cleaning agents or those
which are harmful or environmentally unfriendly.

Do not use cleaning agents which contain solvents.

Only use suitable cleaning agents to remove ex-
treme dirt.

Check suction and discharge grille regularly to see
whether it is dirty and clean it, when necessary.

Check the suction opening for combustion air as well
as the injector fitted behind it and the gas nozzle
regularly to make sure that they are not dirty.

Check gas hoses and gaskets to see whether they
are damaged and replace when necessary.

Clean gas burner and gas nozzle regularly.

Clean baffle plate regularly.

Check ignition electrode and clean when necessary.

Set the ignition electrode when necessary.

3 mm distance from the burnerhead.

Check thermocouple and clean when necessary.

Intensive yellowish flames indicate that the fresh
air supply is probably insufficient and that there is
some dirt inside the unit, respectively.

The bi-metal spring may neither be damaged nor
bent in or order not to affect the function of the
temperature-limiter!

1. Remove four fasten-

ing screws 1.

2. Pull off the outside

casing to the front.

1

When the unit is being maintained, set or repaired,
the gas supply has to be cut off and the mains plug
has to be unplugged from the mains socket!

Control the functions of the complete unit and
carry out a tightness check for all gas-bearing con-
nections using soap solution and leakage detec-
tion spray, respectively.