– unit doesn’t start

– unit stops during operation

– fan blows, but gas supply is blocked
resp. no ignition

– flame goes out after having released the pin of
thermoelectric gas valve

– gas supply is blocked, resp. flame goes out

– fuel consumption is too high

– unit can’t be shut down

– heating capacity drops during continuous operation

1 – 2 – 3 – 4 – 7

2 – 4 – 7 – 12 – 13

4 – 5 – 8 – 9 – 12


8 – 10 – 11


4 – 6 – 7 –10 – 11 – 12 – 13

12 – 15

3 – 14

13

Troubleshooting

cause:

trouble:

cause:

remedy:

1. no electrical connection

-

plug the mains into an appropriate mains socket (230V/1~ 50Hz)

2.

fan motor is overcharged
(fan blows irregularly or is blocked)

-

check fan motor, fan blade and clutch plate and replace if neces-
sary.

3. operating switch defect

-

close gas supply, unplug the mains and replace defect operating
switch

4. no gas pressure on solenoid valve

-

check gas supply

-

check contents of gas bottle(s)

-

check gas hose(s) for damage

-

release hose-break protection resp. replace it

5. no ignition spark

-

set ignition electrode

-

check ignition cable

-

check porcelain insulation of ignition electrode

6. air-suction grille dirty

-

clean air-suction grille

7. unit is shut down by temperature limiter

-

check air-suction and blow-out grille and clean if necessary

-

check fresh air supply

8. safety pilot does not open (resp. does not lock)

-

replace safety pilot

9. piezo electric igniter defect

-

replace piezo electric igniter

10. thermocouple resp. temperature limiter defect

-

check position of thermocouple and adjust according to setting hints

11. loose or dirty connection between safety pilot and thermocouple

-

check connection and clean if necessary

12.

pressure controller defect or false pressure controller mounted
resp. hose break protection is blocked

-

mount original pressure controller

-

release hose-break protection resp. replace it

13

gas bottle(s) iced over due to low temperatures and too high gas
taking

-

replace empty gas bottle(s) and connect 2-3 bottles using multi bot-
tle set (EDV-No. 1014050)

14. solenoid valve does not open

-

close gas supply

-

let flame burn out

-

put operating switch in position „0” and unplug the mains

-

replace solenoid valve

15. leak gas hose(s)

-

find leakage by foam forming mediums eliminate leakage

Make sure that the gas supply has been closed and the mains plug has been taken out of the mains