Customer service and guarantee, Wiring diagram, Technical data – REMKO ETF 220 User Manual
Page 14

14
Proper Use
The units have been designed and equipped exclusively
for dehumidification purposes.
The manufacturer assumes no liability for damage re-
sulting from non-compliance with manufacturer specifi-
cations and legal requirements, or if modifications are
made to the units.
Operation/handling which does not comply with
these instructions is prohibited!
In cases of non-compliance, we assume no liability
and the guarantee becomes null and void.
Customer Service and
Guarantee
For the guarantee to be valid, the purchaser or his cus-
tomer must completely fill out the "guarantee certificate"
enclosed with all units and send it back to REMKO GmbH
& Co. KG
.
The units are repeatedly tested at the production site to
ensure that they are working properly. If a malfunction
occurs that cannot be eliminated by the operating per-
sonnel, please contact your dealer or contact person.
M1
MV
M2
HI
CN1
CN2
CN3
CN1-A
MS
SP
FS
rt
g
e
w
s
b
l
rt
bl
bl
ws
w
s
b
r
w
s
NS
Wiring Diagram
FS
Frost protection sensor MS Microswitch
M1 Compressor motor
NS Power supply
M2 Fan motor
SP Sensor board
MV Magnetic valve
Technical Data
Series ETF 220
Operating range temperature °C 6 - 32
Operating range humidity % r. h. 40-100
Dehumidification capacity max. l/day 22
at 30 °C / 80 % r.h. l/day 20.6
Air capacity, min./max. m³/h 150/190
Refrigerant R 134a
Refrigerant amount g 340
Electrical connection V 230/1~
Frequency Hz 50
Rated current max. A 3.4
Power consumption max. W 620
Fuse protection (supplied) A 10
Sound pressure level min./max. L
pA
1m
1)
dB (A) 42/46
Dimensions:
Depth mm 315
Width mm 390
Height mm 620
Weight kg 21
1) Noise measurement DIN 45635 - 01 - KL 3