Control Panel


The hygrostat and the control lights are located on the
control panel.

1 Hygrostat

Select the humidity level in the room where the unit
is located using the gradually adjustable hygrostat.

2 “Dehumidification“ control light

This light indicates that the unit is operating properly.

3 “Tank full“ control light

This light indicates that the condensation tank is full
and the unit has switched off as a result.

4 “Defrost“ control light

This light indicates that the automatic defrost system
built into the unit has switched on the defrost cycle.

1

4

3

2

Depending on the air temperature and the relative hu-
midity, the condensed water drips out steadily or only
during periodic defrosting phases into the collection
tray
and then into the condensation tank beneath it
through the integrated drainage lines.
A float regulator flap is installed in the condensation
tank that interrupts dehumidification operation via a mi-
croswitch when the tank is full.
The unit switches off and the LCD display "Tank full“
lights up. It goes off again when the condensation tank
is emptied and replaced. The unit then restarts after a
delay of approximately 2 minutes.
For unsupervised, continuous operation of the unit, the
condensation is continuously drained via an external
water hose.

Setup


Follow the instructions below to ensure the to optimum,
economical and safe operation of your unit.

◊ The unit must be securely placed in an upright posi-

tion so that condensation can drain freely into the
condensation tank.

◊ If possible, place the unit in the middle of the room to

ensure optimum air circulation.

◊ Maintain a minimum distance of 50 cm to walls.

◊ Make sure that the air can flow freely into the back

of the unit and out of the upper air flap.

◊ Do not place the unit in the direct vicinity of radiators

or other heat sources.

◊ Keep the room to be dried or dehumidified closed so

that air from the surroundings cannot get in.

◊ Keep windows and doors closed and avoid entering

and leaving the room frequently.

◊ If the unit is in operation in a dusty environment, the

appropriate service and maintenance measures are
to be undertaken in accordance with the specific
conditions.
See chapter "Maintenance and Service".

◊ You can improve the air circulation if you set up the

unit at a height of approximately 1 m.

Important information about the electrical connec-
tion

◊ The electrical connection of the unit is to be carried

out in accordance with DIN

VDE 0100,

Part 704 to

electrical supply points with residual current circuit
breakers.

◊ When the unit is set up in wet areas such as in bath-

rooms

or kitchens, the unit must be equipped by the

customer with a residual current circuit breaker that
meets regulations.

Fenster

geschlossen

halten

Tür

geschlossen

halten

Wand

absta

nd m

ind. 0

,5m

Ab

sta

nd

zu

He

izk

örp

ern

od

er

and

ere

n W

ärm

equ

elle

n h

alte

n

keep the

window

closed

keep the

door

closed

minim

um dis

tance

of 0,5

m

Ple

ase

ke

ep

dis

tan

ce

to t

he

rad

iato

r o

r o

the

r h

eat

ing

so

urc

es

This manual is related to the following products: