Wiring diagram, Technical data, Customer service and guarantee – REMKO ETF 240 User Manual
Page 11

11
Wiring Diagram
C
Condensator
MS Microswitch
H
Hygrostat
NS Power supply
M1 Compressor motor PA Display circuit board
M2 Fan motor
PS PCB with control
Technical Data
Series
ETF 240
Operating range temperature
°C
6-32
Operating range humidity
% r. h.
40-100
Dehumidification capacity max.
l/day
26
at 30 °C / 80 % r.h
l/day
24,4
Air capacity, max.
m³/h
190
Refrigerant
——
R 134a
Refrigerant amount
g
340
Electrical connection
V
1 ~ 230
Frequency
Hz
50
Rated current max.
A
3,4
Power consumption max.
kW
0,62
Fuse protection (supplied)
A
10
Sound pressure level L
pA
1m
1)
dB(A)
43
Depth
mm
314
Width
mm
390
Height
mm
612
Weight
kg
21
1) Noise measurement DIN 45635 - 01 - KL 3
NS
H
MS
M1
M2
PA
PS
C
ACI
LINE
NATURE
COMP
DEICE
DEICE
bl
bl
bl
bl
bn
bn
ge
or
rt
ws
ws
rt
rt
ws
rt
ge
ws
ws
230 1 ~ 50 Hz
Proper Use
The units have been designed and equipped exclusively
for dehumidification purposes.
The manufacturer assumes no liability for damage re-
sulting from non-compliance with manufacturer specifi-
cations and legal requirements, or if modifications are
made to the units.
*
Operation/handling which does not comply with
these instructions is prohibited!
In cases of non-compliance, we assume no liability
and the guarantee becomes null and void.
Customer Service and
Guarantee
For the guarantee to be valid, the purchaser or his cus-
tomer must completely fill out the "guarantee certificate"
enclosed with all units and send it back to REMKO GmbH
& Co. KG
.
The units are repeatedly tested at the production site to
ensure that they are working properly. If a malfunction
occurs that cannot be eliminated by the operating per-
sonnel, please contact your dealer or contact person.