Remko etf 400, Commissioning – REMKO ETF 400 User Manual
Page 10
Starting the unit
1. Move the operating
switch [2] to the "0"
(off) position.
2. Connect unit
mains plug
to a properly
installed
and protected
mains socket
230V/ 50 Hz
.
3. Move the operating
switch [2] to the "0"
(off) position.
4. The green control lamp"
in operation" will illuminate
and the unit will operate in fully-
automatic dehumidification
mode.
Before commissioning the unit
or if local requirements dictate,
the air-inlet grille and air-outlet
grille must be checked for
contamination.
Important points
prior to installation
■
All extensions to the electrical
connection must
be of a sufficient cable size
and must only be used fully
rolled out or unrolled
■
Never use the mains cable
asa pull cord
■
After being switched on,
the units operate fully-
automatically until switched
off by the float when
the condensate container is full
■
The condensate container
must be inserted properly
and the sealing flap must be
locked
Commissioning
Operation and gauge
1
2
3
4
1 = Operating hours counter
2 = Operating switch
3 = Control lamp -GREEN-
"In operation"
4 = Control lamp -YELLOW-
"Container full"
Operation with a humidity
switch
The REMKO humidity switch
(accessories) is supplied with
a special adapter.
The following procedure must
be followed when commissioning
units in conjunction with
a humidity switch:
1. Insert the adapter into
a properly secured mains socket.
2. Place the humidity switch
in a suitable location within
the room being dehumidified.
Not in the immediate vicinity
of the units or sources of heat.
3. Insert the mains plug (or a cable
extension) into the adapter.
4. Set the desired air humidity
on the humidity switch.
5. Move the operating switch [2]
on the unit to position "I".
The units will switch
on automatically when the air
humidity in the room exceeds
the pre-set level on the humidity
switch.
The units will now operate fully-
automatically until the desired
relative humidity (% RH) has
been reached or until the unit
is switched off by the float when
the condensate container is full.
In the event that this occurs,
the yellow "Container full" control
lamp will illuminate.
NOTE
A contaminated grille or filter
must be cleaned or replaced
immediately.
NOTE
In room temperatures below
10°C
and relative humidity
below
40%
, economical
use of the unit can no longer
be guaranteed.
NOTE
The units are only
functional when operated with
a correctly inserted condensate
container.
10
REMKO ETF 400