The unit (fan) does not start.

1. Check the local mains fuses.

2. Check the mains plug.

3. Check the operating switch.

4. Check the fan for smooth

operation.

The unit does not heat

1. Set the thermostat to a value

above room temperature.

2. Check function of the

thermostat.

3. Check the operating switch.

4. Check the function of the

contactor.

5. Check the function of the

temperature limiter and inspect
for damage.

If no result is achieved after
carrying out all functional checks,
an authorised service station
should be contacted.

Troubleshooting

Regular care and the observance
of a few basic conditions will
guarantee trouble-free operation
and a long service life of the units.

Observe regular care and

maintenance intervals

Depending on the particular

operating conditions, the
units should be tested by an
expert for reliable operation
as necessary, however at least
once a year.

Keep the unit free of dust and

other deposits.

Only clean the units dry or with

a moist cloth.

Do not use direct jets of water,

e.g. high pressure cleaners, etc.

Do not use caustic cleaning

agents or those containing
solvents.

Check the air inlet and air outlet

grilles for clogging.

Check the safety and protective

devices at regular intervals.

Do not damage the sensor and

capillary tube of the thermostat
when removing or fitting the
rear panel of the unit.

Care and maintenance

1. Set the operating

switch to

position “0”.

The supply air fan

continues to run to cool down the

units if necessary and switches

off when an adequately low

temperature is reached.

The fan may run several times until

it switches off permanently!

2. The units must

be disconnected

from the supply

if they are not

going to be used

for extended

periods of time.

Decommissioning

NOTE

Only authorised electricians

may carry out repairs.

ATTENTION

The unit must never be

disconnected from the mains

supply before the cooling

phase has ended.

Damage attributed to

overheating is not covered by

the warranty.

ATTENTION

After completing all work

on the unit, an electrical

inspection must be carried out

according to VDE 0701.

ATTENTION

Before carrying out all work
on the unit, the mains plug
must be disconnected from the
mains socket-outlet.