Operation

The units can be used for air
heating or only air circulation
depending on the respective mode
selected (switch position 1).
The units have two heat settings
(switch positions 2 and 3).

In order to ensure a constant room
temperature, the units have an
integrated room thermostat.
The thermostat switches off the
heater when the set temperature
is reached and switches it on again
when the temperature falls below
the set value.

The integrated temperature
limiter switches off the unit if the
temperature is excessively high and
switches it on again automatically
after it has cooled down.

After switching off the unit at
the operating switch or room
thermostat, the air supply fan
continues to run for a certain
period of time to cool the heating
resistors
and switches off automatically.

Commissioning

Heat

The unit operates fully
automatically depending on the
temperature set at the thermostat.

1. Setting the required

room temperature
at the thermostat

2. Set the operating

switch to the
required heat
output - position
“2” = 4.5 kW or
“3” = 9 kW.

Fan

In this position, only the supply air
fan runs. Thermostatic control and
heating are not possible.

1. Set the operating

switch to position
“1” Fan.

Operation and monitoring of the
units must be carried out by one
person who has been adequately
instructed in the use of the unit.

1. Check the system voltage for

correspondence with the unit
voltage 400V/3~N/50 Hz.

2. Set the operating

switch to position
“0” (Off).

3. Plug the unit

into a properly
installed mains
socket-outlet.
400V/3~N/50Hz

NOTE

Electrical connection of the
units must be made at a
separate supply point using
a residual-current-operated
circuit-breaker according to
VDE 0100 § 55.

NOTE

For optimal operation, the
units should not be operated
at ambient temperatures above
25°C.

ATTENTION

Only authorised electricians
may extend the connecting
cable taking into account the
rating of the unit, cable length
and use locally.

ATTENTION

All cable extensions must
be used only uncoiled or
unwound.

ATTENTION

The unit must never be
disconnected from the mains
supply before the cooling
phase has ended.
Damage attributed to
overheating is not covered by
the warranty.