Safety instructions, Starting, Description of the unit – REMKO ELT 3-2 User Manual
Page 4
4
2. Put operating switch into
position "0".
3. Connect the unit-plug to an ade-
quate mains socket..
Safety Instructions
REMKO electric heaters will provide you with high utility
and long life thanks to our extensive material, function
and quality controls. Dangers may arise nevertheless if
the unit is used by persons not familiar with its opera-
tion or if the unit is not used for its intended purpose.
The persons charged with the operation of the units
have to check these before starting work as to visible
defects of the operation and safety devices, as well as
to make sure that no protective devices are missing.
In the case of faults the supervisor is to be informed.
In the case of faults which endanger the safe opera-
tion of the units, the units are to be stopped!
During the operation of the units the applicable local
regulations are to be observed and the relevant
safety measures to be taken.
Make sure that the prescribed safety distances from
combustible objects are observed!
A free air suction and air discharge must be en-
sured.
The blow off opening of the unit may not be narrowed
or equipped with hoses or conduits.
Never place foreign objects into the unit.
Do not cover the units during operation.
The units may not be operated near bath tubs,
showers, swimming pools, etc.
The units may not be operated directly beneath a wall
socket.
The units may not be exposed to direct water jets.
Make sure that no water penetrates inside the units.
The units may not be operated in rooms which are
endangered by explosions.
Protect all electric cables outside the units from
damage (e.g. caused by animals).
Starting
A well trained person is to be charged with the opera-
tion and control of the units.
1. Check the main voltage is in accordance with the
unit voltage.
ELT 3-2 230V/1~
ELT 10-6 and ELT 18-9 400V/3~
Description of the Unit
The units are operating with electric energy and are
suitable for a fully automatic, all-purpose and simple ap-
plication.
The units are equipped with capsuled electrical heating
elements, noiseless maintenance-free axial fans, safety
and after-cooling thermostat, thermostat socket and
connecting cable with plug.
The units are in accordance with the basic safety and
health requirements of the relevant EC – regulation.
The units are handled simply and are safe in operation.
Application
Drying of new buildings, spot heating of working
places outside or in fire-proof halls and production
places.
Permanent or temporary heating of rooms.
Defrosting of machines vehicles and fire-proof stor-
ing goods with keeping the prescribed distance of
safety.
Connecting cable extensions may be laid exclu-
sively by authorised electricians based on the
unit capacity, cable length and taking the local
terms of use into account.
Working of the unit
All units can be used for heating or ventilation by setting
the equivalent mode on the operating switch.
The unit ELT 3-2 has got exclusively on heating stage
and has a 2 step operating switch.
The units ELT 10-6 and ELT 18-9 has got three heating
stages.
The units can be operated with a room thermostat
(accessories) which is ready to be plugged in, to ensure
a constant room temperature. When the pre-selected
temperature has been reached, the thermostat stops
the heating operation to restart it when the temperature
has fallen below the set value.
When the units have been switched off by the operating
switch or the room thermostat, the supply air fan contin-
ues running for a certain time to cool down the heat ex-
changer, and then it stops automatically.
ELT 3-2
ELT 10-6
ELT 18-9
The electric connection of the units is to be carried
out via a special supply point with fault current
safety switch.