Infrared remote control – REMKO MKT 3502 Neutral User Manual
Page 7
7
Infrared Remote Control
Inserting the batteries into the remote control
Prior to initial operation, the batteries supplied with the
unit (2 type AAA batteries) must be inserted into the re-
mote control.
1.
Slide off the cover of the battery slot on the back
of the remote control.
2.
Place the batteries in the slot making sure that
the polarity is correct.
Use the labelling in the slot.
3.
Close the cover.
General Information
The infrared remote control must be protected from
moisture.
When the unit is switched on, each change in the
settings is automatically transferred to the air condi-
tioner. A beep indicates that the data has been prop-
erly received.
The transmitter of the infrared remote control must
generally transfer changes to settings in the direc-
tion of the air conditioner.
It is only possible for data to be properly transmitted
if there are no objects located between the transmit-
ter and the receiver unit such as doors, drapes,
blinds, etc.
Never use new and old batteries at the same time!
We recommend removing the batteries from the re-
mote control if the unit is taken out of operation for a
longer period of time.
Remove dead batteries and immediately replace
them with new batteries that meet quality stan-
dards because otherwise they may leak.
Infrared Remote Control Functions
All settings can also be made using an infrared remote
control. A description of the button functions can be
found in the “Control Panel” section. The remote con-
trol’s range is approx. 5 meters.
Two 1.5 V AAA batteries (included in the scope of the
remote control delivery) power the remote control.
1 “ON/OFF” button
2 “MODE” button
3 “TIMER” button
4 “AUTO SWING” button
5
▲
/
▼
“THERMO CONTROL” buttons
Keep in mind that if there is no plug or it is inserted
incorrectly, water may leak out after the unit has re-
sumed operation.
POWER
on / off
THERMO
CONTROL
MODE
TIMER
AUTO
SWING
reset
set
1
5
2
3
4
12 “DRAIN WATER” display
This light indicates that the floating switch of the
internal tank has switched off unit operation. The
internal tank does not become full during normal
operation because the exhaust fan transports the
accumulated and evaporated condensation to the
outside via the exhaust hose. In conditions with
very highs levels of humidity, the moisture cannot
be completely expelled and the unit switches off.
To resume unit operation after it has automatically
been switched off due to a malfunction, proceed as
follows:
1. Switch the unit off by pressing the “On/Off” but-
ton and unplug it from the power supply.
2. Place a suitable container under the condensa-
tion drain of the internal tank.
The condensation drain is located at the bottom
middle at the back of the unit.
3. Pull the plug from the condensation drain and
collect the water that drains out.
4. Then replace the plug.
13 Display
The programmed room temperature is shown on
the display.
The current temperature value is increased or de-
creased by pressing the Up/Down buttons 3 and 4.
If the timer button 5 is pressed, the display switches
to show the remaining hours until the unit is
switched on or off.
If after 5 seconds, no buttons are pushed, the tar-
get temperate appears on the display again.
14 Infrared remote control receiver
If the unit is operated using the infrared remote
control, the impulses are received via the receiver.