Technical data, Customer service and guarantee, Environment and recycling – REMKO MKT 3502 Neutral User Manual
Page 12
12
1) Room temperature WB 35°C/DB 24°C
2) Distance 1m
Customer Service and
Guarantee
For the guarantee to be valid, the purchaser or his cus-
tomer must completely fill out the “guarantee certificate”
enclosed with all units and send it back.
The units are repeatedly tested at the production site to
ensure that they are working properly. If a malfunction
occurs that cannot be eliminated by the operating per-
sonnel, please contact your dealer or contact person.
Only authorised personnel may come into contact with
the cold cycle. This ensures that refrigerant does not
escape into the environment when the unit is being re-
paired.
Both the refrigerant and the system parts are subject to
special requirements for disposal. The refrigerant in use
is a safety refrigerant. This means that, should damage
occur, the quantities released will not cause injury to the
respiratory systems of people and animals.
Important information about recycling!
Environment and Recycling
Do not touch the liquid refrigerant as it can freeze the
skin!
Operation/handling which does not comply with
these instructions is prohibited!
In cases of non-compliance, we assume no liability
and the guarantee becomes null and void.
Proper use
The manufacturer assumes no liability for damage re-
sulting from non-compliance with manufacturer specifi-
cations and legal requirements, or if modifications are
made to the units.
Technical Data
Type designation
Nominal cooling capacity
1)
kW
Energy efficiency class cooling
Energy efficiency ratio EER
Dehumidification capacity max.
l/h
Operational area (size of room), approx.
m³
Operating range indoor unit
°C / % r.F.
Refrigerant
Operating pressure max., refrigeration cycle
kPa
Refrigerant, basic quantity
kg
Circulating air volume per speed
m³/h
Sound pressure level per speed
)
dB(A)
Power supply
V/Ph/Hz
Protection type
IP
Nominal power consumption
1)
kW
Nominal current consumption
1)
A
LRA
A
Operating medium
Exhaust air hose, length / diameter
mm/mm
Dimensions
height
mm
width
mm
depth
mm
Weight
kg
Serial number
Ref. No.
MKT350/2
3.45
A
2.63
2.0
100
18 to 35 / 35 to 85
R 407 C
1900 / 2800
0.75
380 / 430 / 450
49 / 51 / 52
230 / 1~ / 50
IP 20
1.31
5.98
Fresh air, max. 80% relative hu-
midity
1250 / 125
825
450
380
35.0
631...
569...
1615350
1615351
25