Item

How Often

How To

Fuel tank

Flush every 150-200 hours

See Storage above.

of operation or as needed.

Air output and

Replace every 500 hours of

See Air Output, Air Intake,

lint filters

operation or once a year.

and Lint Filters, page 10.

Air intake

Wash and dry with soap and

See Air Output, Air Intake,

filter

water every 500 hours of op-

and Lint Filters, page 10.

eration or replace as needed.

Fuel filter

Clean twice a heating season

See Fuel Filter, page 11.

or replace as needed.

Spark plug

Clean and regap every 600

See Spark Plug, pages 11

hours operation or replace

and 12.

as needed.

Fan blades

Clean each season or as needed. See Fan, page 10.

Motor

Not required/permanently lubricated

WARNING

!

PREVENTATIVE

MAINTENANCE

SCHEDULE

Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.

STORAGE

1. Drain fuel tank.

Note:

Some models have drain plug on underside of fuel tank. If so, remove

drain plug to drain all fuel. If heater does not have drain plug, drain fuel
through fuel cap opening. Be sure all fuel is removed.

2. Replace drain plug if used.
3. Add one gallon of clean kerosene to fuel tank.
4. Attach fuel cap.
5. Move heater forwards and backwards to stir fuel.
6. Remove fuel cap or drain plug and drain fuel tank. Be sure all fuel is removed.
7. Replace fuel cap or drain plug. Properly dispose of old and dirty fuel.
8. Store heater in dry place. Make sure storage place is free of dust and corrosive

fumes.

IMPORTANT:

Do not store kerosene over summer months for use during next

heating season. Using old fuel could damage heater.

To Stop Heater

1. Unplug extension cord from outlet.

To Restart Heater

1. Wait two minutes after stopping heater.
2. Repeat steps under To Start Heater, page 7.