MAINTENANCE

1. Turn off engine and/or disconnect all electrical power before performing maintenance.
2. EVERYDAY:

• Turn control fully from 0 to 100 taking care not to force the control past it's stopping points.

3. EVERY 3 MONTHS:

• Inspect repair and/or replace any cracked parts or frayed cords.
• Replace any unreadable labels.

®

®

1

2

WARNING!

Read and understand all safety messages in this and the welding power source owner's manual.

SAFETY

SMOKE, FUMES AND GASES can be
hazardous to your health.
• Keep head away from fumes and smoke.
• Ventilate work area

ARC RAYS can burn eyes and skin.
• Wear correct body protection
• Wear welding helmet with filter.

WELDING can cause fire and explosion.
• Do not weld on closed containers.
• Watch for fire

ELECTRIC SHOCK can kill.
• Do not touch live electrical parts
• Keep all panels in place.
• Keep yourself insulated from the work

DIMENSIONS

HEIGHT 9 in. (229 mm )
WIDTH 7 in. (178 mm )
DEPTH 8 in. (203 mm )

WARRANTY

LIMITED WARRANTY - Subject to the terms and conditions hereof,
PROFAX, Pearland, TX warrants it's products to be free from defects in
workmanship and material at the time of delivery by PROFAX.

PROFAX will honor warranty claims on products as a result of failure from
a defect for a time period as listed below for the particular product line,
from date of sale to the original user.

Consumable products manufacturered by PROFAX......................... 30 Days
Resale consumable products.................... Original Manufacturer's Warranty
Mig Guns, Flux Cored Guns, Spool Guns........................................ 90 Days
Arc Gouging Torches, Plasma, Tig Torches & CO

2

Heaters.............. 90 Days

Remote Fingertip, Hand/Foot Controls............................................ 90 Days
Voltage Controls & Spool Guns...................................................... 90 Days
Spool Gun Controls....................................................................... 1 Year
Welding Power Sources & Wire Feeders......................................... 3 Year
Shelf Life Before WARRANTY Starts ........................................... 1 Year

Upon return of the merchandise at user's expense, PROFAX reserves the
right to either repair or replace as necessary.

This is the only warranty either expressed or implied covering
PROFAX products.

D

W

H

INSTALLATION

WARNING!

Electric Shock can kill.

• Do not touch live electrical parts.
• Shut off welding power source and disconnect all electrical power.
• Shut off engine before making electrical connections.
• Keep all panels securely in place.

CAUTION! Incorrect installation can damage unit.

• Double check installation instructions

1. Turn off welding power source or stop engine on welding generator.
2. TWISTLOCK PLUG:

• Make connection by aligning plug to mating receptacle on power source, inserting plug into the receptacle

and turning clockwise as far as it will go.

3. If the power source has a Contactor Switch - place it into the STANDARD or PANEL position.
4. If the power source has a Current or Voltage control switch - place it in the REMOTE position.

TROUBLESHOOTING

1. NO AMPERAGE OR VOLTAGE CONTROL

• Check switches and controls on power source for proper position.

Remote Contactor Switch ------------Standard position (contactor on)
Remote Current or Voltage Switch --- Remote position

• Check plug on hand control to see if it is connected properly to receptacle on power source.
• Check control, cord and plug for broken wires or parts.

2.

NO OUTPUT

• Check weld output on welding power source or generator.

(see power source owners manual)

REMOTE HAND CONTROL SELECTION GUIDE

MODEL

PART NO.

LENGTH

COMPATIBLE EQUIPMENT

®

MHC-3

MHC-3

No Cord

Used on all MILLER equipment that has the 030-653

MHC-3-25

25ft. Cord

(15 ohm) rheostat.

®

MHC-3-50

50ft. Cord

330, 340, & 360 ABP, CP750E, DIALARC HF, FC6E,

®

®

MHC-3-100

100ft. Cord

MK IV EXPRESS , MK VIII -2, SR150, SR200, 300, 400, & 600,
MP30E, 45E, 65E & 75E, SRH222, 303, 333, 404,

555 & 666

®

MHC-3GD34A

MHC-3GD34A

No Cord

Used on all MILLER engine drive equipment that uses

MHC-3GD34A-25

25ft. Cord

the 605-960 (34 ohm) rheostat.

®

®

®

®

MHC-3GD34A-50

50ft. Cord

BIG 20G , BIG 25D , BIG BLUE 250D, BIG BLUE 251D,

®

®

®

MHC-3GD34A-100

100ft. Cord

BIG 40 , BIG 40 D, BIG D4, BIG BLUE 400D,

®

®

BIG BLUE 400D AIRPAK , WD-5, WILDCAT 350G & 350D

REMOTE

MCGD-40A

Remote facilities for installing the MHC-3GD34A remote hand

®

FACILITIES

control onto MILLER engine driven power sources that have the
605-960 (34ohm) rheostat.

®

®

Miller is the trademark of Miller Electric Mfg. Co.

WIRING DIAGRAMS

X

Black

Green

White

Y

WH

PX030-653 Rheostat

REAR VIEW

PX605-797

Twistlock Plug

REAR VIEW

Black
White

Green

Silver

Brass

PX 605-960 Rheostat

REAR VIEW

9328

Twistlock Plug
REAR VIEW

MHC-3

MHC-3GD34A