beautypg.com

Posiflex CR-2000 Series User Manual

Page 5

background image

Part 5

CR-2005:

1).

The drawer number (PID) is default to be 7. Refer to the guidance for
“Jumper Setting Change” below if the PID has to be changed.

2). Connect USB type B connector (more or less square one) of USB

cable to the USB connector at rear side of CR-2005 and the type A
connector end to USB port of host (PC or POS) system as shown in
drawing above.

3).

Check the specification of power adaptor on its nameplate. Insert the
power adaptor into the correct power outlet. Insert the output plug to
the power jack at rear side of CR-2005 to supply power for drawer
kickout.

4).

Turn the keylock to standby position.

5).

Install the USB utility driver from Posiflex Product Information CD
with Posiflex POS system or visit our web sites
http://www.posiflex.com or http://www.posiflex.com.tw or
http://www.posiflexusa.com for latest updates.

Jumper Setting Change:

1).

Use key to open the cash drawer. Take out the removable tray and you
can find a control board in the bottom. The lay out of the control
board is illustrated below.







2).

USB PID select: jumpers over pins 3-4, 5-6 or 7-8 define a drawer
number for the cash drawer as in below table so that this cash drawer
is going to respond accordingly in USB communication. Please note
that within each system there should never be any 2 USB interface
cash drawers carrying the same drawer number.

USB PID

JP1 pins

0 1 2 3 4 5 6 7

3-4 Short Short Short Short

Open Open Open Open

5-6 Short Short Open Open

Short Short Open Open

7-8 Short Open Short Open

Short Open Short Open

JP1

2

1

This manual is related to the following products: