beautypg.com

Connecting sensors, 8/16 channel, Connecting control outputs – OpenEye Gen6 X-Series Hardware Manual User Manual

Page 25

background image

Connecting Sensors

Each recorder may have up to 16 Sensor inputs. These inputs can be used with devices such as
infrared devices, motion device, glass breakage alarms, door and window trips, and many more. The
Sensors can be set to Normally Open or Normally Closed inside the software.

There are 4 Common Grounds (-) and 16 sensor inputs (+). There is no power supplied to the ports so
an external power supply must be used if power is necessary.

8/16 Channel

Connecting Control Outputs

Each recorder may have up to 4 Control Outputs. These outputs can be used to trigger devices such as
Sirens, Phone Dialers, Lights, and any other relay activated device. There is no power supplied to the
ports. Use an external power supply if necessary.

8/16 Channel

Use 12V, below 300mA. For controlling lights or other devices, use another external relay.

Maximum voltage is 24V AC @ 1 amp

Output uses a Form C Relay

(+)

(-)

Siren, Alarm, Outside Relays

External Power Supply (DC 12V)

Common Ground

Sensor Inputs

32520AB

25