GENERAL SPECIFICATIONS
ACCURACY
• ± 0.4% of reading from 3.3 to 33 ft/sec
• ± 0.8% of reading from 1 to 3.3 ft/sec
• ± 2.0% of reading from 0.4 to 1 ft/sec
SENSING METHOD
Electromagnetic sensing (no moving parts)
AVAILABLE METER SIZES
(nominal pipe diameters in inches)
1, 1½, 2, 3, 4, 6, 8, 10, 12, 14, 16, 18, 20, 24, 26, 30,
34, 36, 40, 42 & 48 (Inquire for other sizes)
LIQUID TEMPERATURE RANGES
32° to 130° F
BODY MATERIAL
Heavy duty plastic enclosure with
sliding door for battery
RATE IDICATOR
• Type: Six digit LCD with 0.46” numbers
• Calibration: Set at the factory to read turbine
frequency in Hertz. A conversion chart allows the
user to convert frequency to volumentric flow rate
(GPM) in any pipe size. Factory will set to read
GPM or any other units for particular pipe size upon
request.
• Field programming possible
• Memory: Non-volatile E2PROM memory retains
all programming parameters and count value in the
event of power interruption
POWER SUPPLY
9 Volt battery (NEDA Type 1604) in rear compart-
ment powers the flow meter and LCD display
OUTPUT SIGNALS PROVIDED
• Isolated 4 – 20mA analog output for flow rate
• (2) Programmable pulse outputs (open collector)
AMBIENT TEMPERATURE RANGE
32° to 130° F
ELECTRICAL CONNECTIONS
Pre-wired inline cable connector for flow meter con-
nection
Note: Specifications are subject to change without
notice