beautypg.com

ONICON F-5100 Inline User Manual

Page 13

background image

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]

F-5100 Inline Thermal Mass Flow Meter Manual 05/15 - 0686-11 / 18332

Page 13

ANSI Class 150 Flanged inline sensor dimensions (inches)

ANSI Class 300 Flanged inline sensor dimensions (inches)

D

L

H

D

L

H

Bolt pattern for 4”

flanged meter

Bolt pattern for

½” - 3” flanged meter

¼

½

¾

1

2

3

4

L

n/a

n/a

7

8

10

12

12

12

12

12

12

D

n/a

n/a

3.5

2.88

4.25

4.62

5

6

7

7.5

9

H

n/a

n/a

12.38

12.76

13.13

13.5

13.88

14.88

15.88

16.38

17.88

¼

½

¾

1

2

3

4

L

n/a

n/a

7

7

8

10

12

12

12

12

12

D

n/a

n/a

3.75

4.62

4.88

5.25

6.12

6.5

7.5

8.25

10

H

n/a

n/a

12.63

13.5

13.76

14.13

15

15.38

16.38

17.13

18.88

3.2.2 Flanged Meter

Installation Instructions

1.

Apply AGA approved paste sealant or tape sealant to the male NPT threads.

2.

Tighten fittings as per ANSI standards for NPT pipe fittings.

3.

Leak test all connections.