Ordering information – ONICON FB-3500 Series User Manual
Page 8
11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
FB-3500 Bi-Directional Insertion Electromagnetic Flow Meter Manual 05/14 - 0718-3
Page 8
1.5 ADDITIONAL HARDWARE THAT MAY BE REQUIRED
1.5.1 Grounding Rings
Grounding rings may be required whenever meters are installed in non-metallic or lined pipes.
Grounding rings placed before and after the meter eliminate electrical noise that will interfere
with the proper operation of the meter. ONICON provides grounding rings as an optional
accessory. Grounding ring dimensional information and part numbers are listed below. For proper
operation, grounding rings are required before and after the meter.
ORDERING INFORMATION
ANSI Class 150
316 Stainless Steel
Grounding Rings (pair)
Nominal
Size
ONICON Part
Number
1”
19265
1½”
19266
2”
19267
3”
19268
4”
19269
6”
19270
8”
19271
10”
19272
12”
19273
14”
19274
16”
19275
18”
19276
20”
19277
24”
19278
30”
19279
36”
19280
42”
19281
Grounding Ring Dimensions
Nominal Size
Bore
A
C
D
1”
1 - 1/16
2 - 5/8
4 - 9/16
1 - 15/16
1.5”
1 – 9/16
3 – 3/8
5 - 5/16
1 - 15/16
2”
2 – 1/16
4 – 1/8
6 - 1/16
1 - 15/16
3”
3 – 1/16
5 – 3/8
7 - 5/16
1 - 15/16
4”
4 – 1/16
6 – 7/8
8 - 13/16
1 - 15/16
6”
6
8 – 3/4
10 - 11/16
1 - 15/16
8”
8
11
12 - 15/16
1 - 15/16
10”
9 – 1/2
13 – 3/8
15 - 5/8
2 - 1/4
12”
11 – 9/16
16 – 1/8
18 - 9/16
2 - 7/16
14”
13 – 1/2
17 – 3/4
20 - 3/8
2 - 5/8
16”
15 – 1/4
20 – 1/4
22 - 7/8
2 - 5/8
18”
17 – 3/8
21 – 5/8
24 - 1/4
2 - 5/8
20”
19
23 - 7/8
26 - 11/16
2 - 13/16
24”
23
28 – 1/4
31 - 1/8
2 - 7/8
30”
29
34 – 3/4
38
3 - 1/2
36”
35
41 – 1/4
45 - 1/4
4
42”
41
48
52 - 1/2
4 - 1/2
D
C
3/8
5/8
Bore
A
1/4
1/8”
10 DIA
Gasket (4PL)
Grounding Ring (2PL)
Flow Direction
10 DIA
Typical Installation
Non-conductive Pipe
DIMENSIONS