Olson Technology OTOHP-RFG User Manual
Page 5
INSTALLATION (CONT.)
FRONT PANEL NUMERIC DISPLAY OPERATION DESCRIPTION
Note: If the power supply turns on after the OTOHP-RFG quad RFoG receiver is
inserted, the Display LED will flash for 5 seconds, and indication the receiver is self-
checking.
6
Verify that the correct optical connector will be attached to the optical connector on
the module. Clean both the bulkhead and fiber connectors.
7. Connect the optical fibers to the appropriate OPT IN adaptor on the rear panel.
8. Connect the RF cord to the appropriate RF OUT connector on the rear panel.
9. Push SET button and set RF TP channels. Using a signal level meter, measure the
RF output at the RF TP test point (20dB below actual level) on the front panel and
verify that it is set at the specified value for that channel. Further adjust the RF
output level if required using MGC function.
First push SET on the LED display and set function.
.
A01: MGC setting menu
A02: Test Port selection menu
A03: Alarm menu
Push
and
to view
the alarm
code.
x
x
Press Exit to
Jump to A03
Press Exit to
Jump to A02
Press Exit to
Jump to CH1
A 0 1
A
A
0
0
2
3
X X
C H 2
C H 3
C H 4
1
0 0 X
X
H 1
X
X
X X
C
Twin
-kle
Twin
-kle
...
...
...
SET
EXIT
Twin
-kle
Press SET, tens digit will twinkle.
Press and to set it. Press SET to
complete the tens digit setting. Now
the ones digit is twinkling.
Press and to set it. Press SET to
complete setting the ones digit.
Push and
to set TP.
Press SET
to complete
setting.
x
EXIT
SET
EXIT
SET
SET
SET
SET
SET
SET
SET
SET