INSTALLATION (CONT.)

FRONT PANEL NUMERIC DISPLAY OPERATION DESCRIPTION

Note: If the power supply turns on after the OTOHP-RFG quad RFoG receiver is
inserted, the Display LED will flash for 5 seconds, and indication the receiver is self-
checking.

6

Verify that the correct optical connector will be attached to the optical connector on
the module. Clean both the bulkhead and fiber connectors.

7. Connect the optical fibers to the appropriate OPT IN adaptor on the rear panel.
8. Connect the RF cord to the appropriate RF OUT connector on the rear panel.
9. Push SET button and set RF TP channels. Using a signal level meter, measure the

RF output at the RF TP test point (20dB below actual level) on the front panel and
verify that it is set at the specified value for that channel. Further adjust the RF
output level if required using MGC function.

First push SET on the LED display and set function.

.

A01: MGC setting menu
A02: Test Port selection menu
A03: Alarm menu

Push

and

to view

the alarm

code.

x

x

Press Exit to
Jump to A03

Press Exit to
Jump to A02

Press Exit to

Jump to CH1

A 0 1

A

A

0

0

2

3

X X

C H 2

C H 3

C H 4

1

0 0 X

X

H 1

X

X

X X

C

Twin

-kle

Twin

-kle

...

...

...

SET

EXIT

Twin

-kle

Press SET, tens digit will twinkle.

Press and to set it. Press SET to

complete the tens digit setting. Now

the ones digit is twinkling.

Press and to set it. Press SET to

complete setting the ones digit.

Push and

to set TP.

Press SET

to complete

setting.

x

EXIT

SET

EXIT

SET

SET

SET

SET

SET

SET

SET

SET